One, shrinkage machine temperature rise slowly or cannot rise to higher temperature (160 degrees Celsius above) is what reason?
Answer: the circuit of the heater is the main power line through a magnetic switch and then to the electric heat pipe, so it should first check whether the magnetic switch contacts are normal.
If the line does not pass through one of the phases, the above phenomenon occurs.
If the magnetic switch is normal, check the meter again to see whether each phase is the same as the ohm value of the machine.
If the normal should be short circuit, if all phases are switched on but the circuit or electric heat pipe is still abnormal, then the heater should be replaced.
Ii. When LSA model is working, the membrane material is easy to shift and cannot be normally fed. How to adjust it?
A: in the L-type machine, if the film material deviation is encountered, the position of the film roll and the tension balance bar are not effective by adjusting the Angle of the upper triangular plate to solve this problem.
If the upper membrane material deviates from the clamping chain, the upper triangular plate can be adjusted clockwise;
If the following film material deviates from the clamping chain, the upper triangular plate can be adjusted counterclockwise.
Iii. When LSA-504C model packs a 6-bottle cluster package, the electric eye cannot detect the package, and it is easy to cut the package when the machine is working. How should it be adjusted?
A: The gap of each bottle of cluster packaging will affect the detection of electric eye. At this time, the detection Angle of horizontal electric eye can be adjusted to bevel Angle.
After adjustment, it can reduce the probability that the electric eye can detect the gap of packaging, so as to avoid the random cutting phenomenon in the work.