What are the failures and handling of liquid packaging machine?
Liquid packaging machine is a modern kind of commonly used mechanical packaging equipment, but the fault of liquid packaging machine is also more frequent, so, liquid packaging machine fault and processing what?
Next, Xiaobian will take you to understand the relevant fault treatment methods of liquid packaging machine, and take a look at it.
1. When circuit breakers of packaging machinery and equipment refuse to close, common electrical circuit faults and mechanical faults refuse to close, basically in the process of closing operation and reclosing.
There are two main reasons for the failure: one is electrical failure, the other is mechanical reasons.
(1) Common electrical faults.
(1) The electrical circuit fault of the circuit breaker of the packing machine may be: if the red and green indicator lights are not bright before the closing operation, the control state road has broken line phenomenon or no control power supply.
Can check the control power supply and the whole pull circuit components are normal.
For example, whether the operating voltage is normal, whether the fuse is broken, whether the anti-jump relay is normal, whether the auxiliary contact of the circuit breaker is good, whether there is pressure, hydraulic closed mirror, etc
(2) When the red light is not on after the operation is closed, the green light flashes and the accident speaker rings, indicating that the position of the handle and the position of the circuit breaker do not correspond, and the circuit breaker is not closed.
Its common original:
A. Melt of the closing circuit fuse is broken or badly contacted.
B. Closing contactor does not operate.
C. Closing coil failure.
(3) when the operation of the automatic vacuum packing machine circuit breaker closed, the green light goes out, the red light is on, but the red light and off the green light flash, the accident loudspeaker rings, indicating that the circuit breaker is closed after automatic tripping.
The reason may be that the circuit breaker is closed on the fault line, causing the protective action trip or the mechanical fault of the circuit breaker, and the circuit breaker cannot be kept in the closed state.
(4) if the green light goes out after the operation is closed, the red light is not on, but the ammeter has been indicated that the circuit breaker has been co-operated.
Possible causes are poor contact of circuit breaker auxiliary contacts or control switch contacts, or loop impassability due to trip coil disconnection, or control loop fuse failure, or indicator bulb damage.
⑤ Operator handle return too early.
The DC power supply of the switch circuit is grounded at two points.
All landowners SF6.
Circuit breaker gas pressure is too low, the density relay closed the operation loop.
The hydraulic pressure is lower than the specified value, the closing circuit is blocked.